Electronic Machine Guarding System

Electronic Machine Guarding System


To operate the MSCD-2 electronic machine guarding system users push a button to disable specific areas of the light screen, so stationary objects such as conveyors, tooling, or fixtures can be positioned in the screen area. This system can sense a change in the blanked area and will go into lockout condition to prevent further machine operation. It is allowed on sensor pairs with 16 sensing beam elements or more, and is limited to a maximum of 12 beams or 30% of the total beams, whichever is less. Programming is also an option. The MSCD-2 is available for 115/230 V AC operation or a 24 V DC model is available, MSCT-2.