Current Limiting Protector, CLiP

Current Limiting Protector, CLiP


Aartech Solonics Limited offers a Current Limiting Protectors (CLiP) that offers the advantages of current limitation for 2.8 through 38 kV systems with continuous current ratings up to 5000 A. Compact, totally sealed construction permits the CLiP to be installed both indoors and out, either pole or structure mounted or within an enclosure. Standard features: a standard 3-phase unit comes complete with interrupters, mounting system using stainless steel channel base, isolation transformers, bus supports, sensing and firing logics, and tinned copper bus with pad for customer connection; sensing and firing logic units have field-selectable trigger level settings with ranges up to 42 kA instantaneous; they do not use transient-susceptible rate of current rise (di/dt) sensing; CLiP units are suitable for indoor use or for outdoor use with or without an enclosure; units are suitable for either 50 or 60 Hz applications; three-phase remote indication of operation provides one relay per phase with 2 NO and 2 NC (form C) contacts for customer fault sensing circuits (located in the control box); and no need to trip all 3 phases for a 1 or 2-phase fault. Use these hi-speed remote indication relay contacts to trip an existing breaker and clear the unfaulted phases. No need to replace interrupters in unfaulted phases; and IP66, NEMA type 4, welded steel, powder-coated remote control box. This contains terminal blocks for user’s power supply and alarm connections, control voltage monitor relay with 2 NO and 2 NC (form C) contacts. All hardware is stainless steel, brass or silicon bronze; the CLiP can be installed in any orientation (with correct positioning of insulators). All control cables are of submersible construction; if the CLiP protective capabilities are not required for a particular mode of system operation, it can be disabled locally or remotely. It then acts simply as a busbar. The operation modes of the CLiP are SCADA adaptable; local indication of operation. A striker pin projecting from one end of an interrupter indicates an operation has occurred; and the control box can be adapted to virtually any AC or DC control voltage supply.

Hi There!

Now get regular updates from IPF Magazine on WhatsApp!

Click on link below, message us with a simple hi, and SAVE our number

You will have subscribed to our Industrial News on Whatsapp! Enjoy

+91 84228 74016

Reach out to us

Call us at +91 8108603000 or

Schedule a Call Back