Safety of machinery: Connectivity makes the difference

  • Industry News
  • Jan 22,24
Integration, networking and linking are important trends in automation technology. Both a machine’s manufacturer and user can reap the benefits of digitisation, such as increased productivity, easy adaptation to individual requirements and improved error diagnosis.
Safety of machinery: Connectivity makes the difference

For many decades, there was only one decision that needed to be made when it came to integrating safety switchgear devices into a machine’s safety circuit – series wiring or parallel. There is now a range of additional options for networking and integration, including fail-safe bus systems, safety fieldboxes and diagnostic fieldboxes. Designers now have a much wider selection to choose from, and need to consider what’s important.  

Tried and tested, and good: the safety bus
Safety bus systems are amongst the solutions that have stood the test of time. A widely used system is the AS-Interface Safety at Work (ASi SaW). Many device series from Schmersal are available with integrated connection for this bus system; the others can be connected via separate interface modules. 

Benefits of this system include the capability to transmit operational and safety signals via yellow ASi flat-ribbon cables. For system manufacturers, this means reduced installation effort and more flexible configuration, while for operating companies, it means more comprehensive evaluation of the operating states of safety switchgear devices. 

The AS-i-Safety standard not only facilitates rapid installation with minimal wiring effort, but also maximum flexibility, for example in the event of system modifications or new requirements and safety requirements. Another advantage is the comprehensive range of diagnostic functions. These make for more rapid identification of the source of error in the event of irregularities or faults. This is particularly beneficial in the case of extensive, complex systems, and can help to reduce downtimes significantly. However, a safety bus can offer benefits for compact machinery with just a few safety switchgear devices and functions as well. 


Different types of safety switchgear device can be connected in series via SD 4.0

Continuous communication from switchgear to higher levels
Schmersal’s SD bus for the capture of operational data, including switching cycles, limit value warnings and distance warnings, is also well tried and tested. In its latest incarnation, designated SD 4.0, these data are captured via a single-wire bus (SD bus for serial diagnosis) and transmitted to an SD gateway or the modular Protect PSC 1 safety controller on a cyclical basis. This creates the prerequisite for clearly simplified networking with higher levels – up to OPC UA as a standardised protocol for M2M communication. 

This form of networking has the advantage of better visualisation of diagnostic information collected in the field, and better access via mobile devices such as tablets and smartphones. The SD gateways are the connection point between the Schmersal SD bus and the traditional fieldbus or an M2M interface, which permit clear visualisation, such as part of a predictive maintenance concept. A specific example: irregularities, such as a misaligned guard door, are displayed to the user so that he can intervene immediately. This helps to improve system availability and to minimise the risk of downtime. In addition, it also enables ‘lean’, cost-saving wiring of as many as 31 safety switchgear devices.

New SD fieldbus gateway with integral web server
Considering these many benefits, it should come as no surprise that Schmersal is working tirelessly to expand this family of products. The SDF Fieldbus Gateway, a new variant that transmits its signals to the machine controller via fieldbus, was showcased at SPS. In addition, the newest SD gateway is also equipped with a web server and a microSD card. This allows the user to evaluate event logs live via the web interface and to read out the entire diagnostic data of all connected safety switchgear devices in plain text in the browser. Moreover, devices, such as solenoid interlocks and control panels, can also be controlled directly via the web interface.


A new SD Gateway with fieldbus connectivity and web server

Open to other fieldbus systems: the Safety Fieldbox 
Apropos fieldbus: the ‘Safety Fieldbox’ system developed by Schmersal allows for connection of up to eight safety switchgear devices of different types (electronic and electromechanical solenoid interlocks, sensors, control panels with emergency-stop function, light curtains, etc) in the field. This helps to reduce costs, especially as the electromechanical and electronic terminal devices only occupy a single device connection each. Both the safety and operational signals are captured and connect to a higher-level control module, such as a safety PLC, using plug and play. 

This could previously be achieved only with the PROFINET/PROFIsafe protocol, the bus system that is most commonly used in Europe. A version with Ethernet/IP-CIP safety interface has also been made available recently. Schmersal showcased the newest version of its Safety Fieldbox with EtherCAT FSoE at SPS. This now allows the designer to plan the safety functions of a machine into a project independently of the fieldbus system that is used, as the three versions together cover the most commonly used control systems globally. 

Three solutions, common objectives 
The three wiring concepts outlined here are simple, cost-effective solutions that can be installed using the plug and play principle. Additionally, these solutions offer extreme flexibility when it comes to adapting the individual safety requirements of complex systems and machinery. Moreover, additional transmission of all diagnostic signals from connected devices ensures optimal process transparency. Plus, increasingly important as an argument is the fact that fewer cables are required, which means that bus systems and network solutions can help to reduce the use of resources like plastic and copper.

Range expansion: a new Safety Fieldbox also communicates via the EtherNet/IP with CIP Safety and EtherCAT with FSoE bus systems

Prospect: new networking concepts, and the elimination of wiring 
Since mechanical engineers are, with good reason, switching to alternative wiring and networking concepts, these systems are undergoing continuous development, and more and more terminal devices are being equipped with the corresponding interfaces. Seen from Schmersal’s perspective, the outlook for the near future includes new versions of the SD Gateway, with additional functions as well as in combination with safety switchgear devices. 

The development continues
If one thing is obvious it is that networking or connectivity will keep pushing ahead – at a higher level and with new features. One such example, and it’s not the only example, is the ‘digital type plate’ of every product in the field and in the control cabinet. In the future, this type plate will not only be stored in the machine’s documentation as part of its digital twin, but will also be retrievable via the M2M interface. This will help to facilitate machine servicing and improve transparency. Connectivity makes it possible.

Related Stories

Auto & Auto Components
Top 10 Global E-Vehicle makers trust Continental Tires in 2023

Top 10 Global E-Vehicle makers trust Continental Tires in 2023

In the Asia-Pacific region, Continental is supplying all five highest-volume manufacturers for the first time, as already in the EMEA and the Americas regions

Read more
Policy Regulation
FTAs boost Engineering exports; shipments to Russia double

FTAs boost Engineering exports; shipments to Russia double

While Russia has become a major trading partner in the last two years largely due to imports of petroleum crude, engineering exports to the country have doubled during April-February this year

Read more
Policy Regulation
DGFT: Exporters must adhere to new UK regulations for duty benefits

DGFT: Exporters must adhere to new UK regulations for duty benefits

The US, European Union (EU), Australia, Japan and many other developed countries grant unilateral import duty concessions to developing countries under their GSP schemes

Read more

Related Products

Fire Alarm Sysytem

INDUSTRIAL SAFETY & SECURITY SYSTEMS

Nayakson Security Systems is offering a range of fire alarm, intrusion alarm and gas alarm systems.


Read more

Request a Quote

Push Button Safety Quick Release Coupling

INDUSTRIAL SAFETY & SECURITY SYSTEMS

Siemag introduces the all new push button safety quick release couplings. Read more

Request a Quote

Surgical Sterile Gloves

INDUSTRIAL SAFETY & SECURITY SYSTEMS

Rising Sun Enterprises is a manufacturer and wholesaler of a wide range of surgical sterile gloves.

Read more

Request a Quote

Hi There!

Now get regular updates from IPF Magazine on WhatsApp!

Click on link below, message us with a simple hi, and SAVE our number

You will have subscribed to our Industrial News on Whatsapp! Enjoy

+91 84228 74016

Reach out to us

Call us at +91 8108603000 or

Schedule a Call Back